Abstract
Several issues may impact on the function of a Fontan circulation including accessory source of pulmonary blood flow and pulmonary artery anatomy. Here we report on a 5.5-year-old boy who showed failing Fontan circulation due to left pulmonary artery stenosis/hypoplasia and significant forward pulmonary blood flow through the native pulmonary artery. Successful implantation of a 34-mm CP covered stent in the left pulmonary artery in a Fontan patient was useful for simultaneous successful treatment of residual antegrade flow from the systemic ventricle to the pulmonary artery and enlargement of hypoplastic left pulmonary artery.
Original language | English |
---|---|
Journal | Catheterization and Cardiovascular Interventions |
DOIs | |
Publication status | Accepted/In press - 2015 |
Keywords
- Covered stent
- Fontan failure
- Fontan operation
- Pulmonary artery
ASJC Scopus subject areas
- Cardiology and Cardiovascular Medicine
- Radiology Nuclear Medicine and imaging