TY - JOUR
T1 - Rapid determination of mycophenolic acid in plasma by reversed-phase high-performance liquid chromatography
AU - Pastore, Anna
AU - Lo Russo, Anna
AU - Piemonte, Fiorella
AU - Mannucci, Liliana
AU - Federici, Giorgio
PY - 2002/9/5
Y1 - 2002/9/5
N2 - A simple, accurate and sensitive high-performance liquid chromatographic method with UV detection was carried out to measure plasma concentrations of mycophenolic acid. Following a simplified acid hydrolysis of the sample, the separation was carried out in 4 min using a Zorbax® Eclipse® C8 reversed-phase column with a flow-rate of 1.5 ml/min, and monitoring the absorbance at 250 nm. Throughput was up to 100 samples in 24 h. Within the investigated concentration ranges of mycophenolic acid (0-100 mg/l), good linearity (r>0.99) was obtained. The method is sensitive (the limit of detection was about 20 μg/l) and precise (for 0.49 mg/l added to plasma, within-run C.V. was 2% and between-run was 4.2%; for 2.88 mg/l, within-run C.V. was 0.35% and between-run C.V. was 0.69%; for 24.38 mg/l, within-run C.V. was 0.77% and between-run C.V. was 3.1%). Analytical recoveries were 96% for 0.5 mg/l mycophenolic acid added to plasma, 100% for 12 mg/l and 102.5% for 24 mg/l.
AB - A simple, accurate and sensitive high-performance liquid chromatographic method with UV detection was carried out to measure plasma concentrations of mycophenolic acid. Following a simplified acid hydrolysis of the sample, the separation was carried out in 4 min using a Zorbax® Eclipse® C8 reversed-phase column with a flow-rate of 1.5 ml/min, and monitoring the absorbance at 250 nm. Throughput was up to 100 samples in 24 h. Within the investigated concentration ranges of mycophenolic acid (0-100 mg/l), good linearity (r>0.99) was obtained. The method is sensitive (the limit of detection was about 20 μg/l) and precise (for 0.49 mg/l added to plasma, within-run C.V. was 2% and between-run was 4.2%; for 2.88 mg/l, within-run C.V. was 0.35% and between-run C.V. was 0.69%; for 24.38 mg/l, within-run C.V. was 0.77% and between-run C.V. was 3.1%). Analytical recoveries were 96% for 0.5 mg/l mycophenolic acid added to plasma, 100% for 12 mg/l and 102.5% for 24 mg/l.
KW - Mycophenolic acid
UR - http://www.scopus.com/inward/record.url?scp=0037026423&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0037026423&partnerID=8YFLogxK
U2 - 10.1016/S1570-0232(02)00353-7
DO - 10.1016/S1570-0232(02)00353-7
M3 - Article
C2 - 12138008
AN - SCOPUS:0037026423
SN - 1570-0232
VL - 776
SP - 251
EP - 254
JO - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
JF - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
IS - 2
ER -