TY - JOUR
T1 - Pulmonary vein isolation in atrial fibrillation patients guided by a novel local impedance algorithm
T2 - 1-year outcome from the CHARISMA study
AU - Solimene, Francesco
AU - Giannotti Santoro, Mario
AU - De Simone, Antonio
AU - Malacrida, Maurizio
AU - Stabile, Giuseppe
AU - Pandozi, Claudio
AU - Pelargonio, Gemma
AU - Cauti, Filippo Maria
AU - Scaglione, Marco
AU - Pecora, Domenico
AU - Bongiorni, Maria Grazia
AU - Arestia, Alberto
AU - Grimaldi, Gabriella
AU - Russo, Maurizio
AU - Narducci, Maria Lucia
AU - Segreti, Luca
N1 - Publisher Copyright:
© 2021 Wiley Periodicals LLC
PY - 2021/6
Y1 - 2021/6
N2 - Background: Highly localized impedance (LI) measurements during atrial fibrillation (AF) ablation have recently emerged as a viable real-time indicator of tissue characteristics and durability of the lesions created. We report the outcomes of acute and long-term clinical evaluation of the new DirectSense algorithm in AF ablation. Methods: Consecutive patients undergoing AF ablation were included in the CHARISMA registry. RF delivery was guided by the DirectSense algorithm, which records the magnitude and time-course of the impedance drop. The ablation endpoint was pulmonary vein isolation (PVI), as assessed by the entrance and exit block. Results: 3556 point-by-point first-pass RF applications of >10 s duration were analyzed in 153 patients (mean age=59 ± 10 years, 70% men, 61% paroxysmal AF, 39% persistent AF). The mean baseline LI was 105 ± 15 Ω before ablation and 92 ± 12 Ω after ablation (p <.0001). Both absolute drops in LI and the time to LI drop (LI drop/τ) were greater at successful ablation sites (n = 3122, 88%) than at ineffective ablation sites (n = 434, 12%) (14 ± 8 Ω vs 6 ± 4 Ω, p <.0001 for LI; 0.73 [0.41–1.25] Ω/s vs. 0.35[0.22–0.59 Ω/s, p <.0001 for LI drop/τ). No major complications occurred during or after the procedures. All PVs had been successfully isolated. During a mean follow-up of 366 ± 130 days, 18 patients (11.8%) suffered an AF/atrial tachycardia recurrence after the 90-day blanking period. Conclusion: The magnitude and time-course of the LI drop during RF delivery were associated with effective lesion formation. This ablation strategy for PVI guided by LI technology proved safe and effective and resulted in a very low rate of AF recurrence over 1-year follow-up.
AB - Background: Highly localized impedance (LI) measurements during atrial fibrillation (AF) ablation have recently emerged as a viable real-time indicator of tissue characteristics and durability of the lesions created. We report the outcomes of acute and long-term clinical evaluation of the new DirectSense algorithm in AF ablation. Methods: Consecutive patients undergoing AF ablation were included in the CHARISMA registry. RF delivery was guided by the DirectSense algorithm, which records the magnitude and time-course of the impedance drop. The ablation endpoint was pulmonary vein isolation (PVI), as assessed by the entrance and exit block. Results: 3556 point-by-point first-pass RF applications of >10 s duration were analyzed in 153 patients (mean age=59 ± 10 years, 70% men, 61% paroxysmal AF, 39% persistent AF). The mean baseline LI was 105 ± 15 Ω before ablation and 92 ± 12 Ω after ablation (p <.0001). Both absolute drops in LI and the time to LI drop (LI drop/τ) were greater at successful ablation sites (n = 3122, 88%) than at ineffective ablation sites (n = 434, 12%) (14 ± 8 Ω vs 6 ± 4 Ω, p <.0001 for LI; 0.73 [0.41–1.25] Ω/s vs. 0.35[0.22–0.59 Ω/s, p <.0001 for LI drop/τ). No major complications occurred during or after the procedures. All PVs had been successfully isolated. During a mean follow-up of 366 ± 130 days, 18 patients (11.8%) suffered an AF/atrial tachycardia recurrence after the 90-day blanking period. Conclusion: The magnitude and time-course of the LI drop during RF delivery were associated with effective lesion formation. This ablation strategy for PVI guided by LI technology proved safe and effective and resulted in a very low rate of AF recurrence over 1-year follow-up.
KW - atrial fibrillation
KW - catheter ablation
KW - DirectSense
KW - lesion formation
KW - local impedance
UR - http://www.scopus.com/inward/record.url?scp=85104965281&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85104965281&partnerID=8YFLogxK
U2 - 10.1111/jce.15041
DO - 10.1111/jce.15041
M3 - Article
C2 - 33851484
AN - SCOPUS:85104965281
SN - 1045-3873
VL - 32
SP - 1540
EP - 1548
JO - Journal of Cardiovascular Electrophysiology
JF - Journal of Cardiovascular Electrophysiology
IS - 6
ER -