TY - JOUR
T1 - Prevention of Atelectasis Formation during the Induction of General Anesthesia in Morbidly Obese Patients
AU - Coussa, Marta
AU - Proietti, Stefania
AU - Schnyder, Pierre
AU - Frascarolo, Philippe
AU - Suter, Michel
AU - Spahn, Donat R.
AU - Magnusson, Lennart
PY - 2004/5
Y1 - 2004/5
N2 - Atelectasis caused by general anesthesia is increased in morbidly obese patients. We have shown that application of positive end-expiratory pressure (PEEP) during the induction of anesthesia prevents atelectasis formation in nonobese patients. We therefore studied the efficacy of PEEP in morbidly obese patients to prevent atelectasis. Twenty-three adult morbidly obese patients (body mass index >35 kg/m2) were randomly assigned to one of two groups. In the PEEP group, patients breathed 100% oxygen (5 min) with a continuous positive airway pressure of 10 cm H2O and, after the induction, mechanical ventilation via a face mask with a PEEP of 10 cm H 2O. In the control group, the same induction was applied but without continuous positive airway pressure or PEEP. Atelectasis, determined by computed tomography, and blood gas analysis were measured twice: before the induction and directly after intubation. After endotracheal intubation, patients of the control group showed an increase in the amount of atelectasis, which was much larger than in the PEEP group (10.4% ± 4.8% in control group versus 1.7% ± 1.3% in PEEP group; P <0.001). After intubation with a fraction of inspired oxygen of 1.0, Pao2 was signifi-cantly higher in the PEEP group compared with the control group (457 ± 130 mm Hg versus 315 ± 100 mm Hg, respectively; P = 0.035) We conclude that in morbidly obese patients, atelectasis formation is largely prevented by PEEP applied during the anesthetic induction and is associated with a better oxygenation.
AB - Atelectasis caused by general anesthesia is increased in morbidly obese patients. We have shown that application of positive end-expiratory pressure (PEEP) during the induction of anesthesia prevents atelectasis formation in nonobese patients. We therefore studied the efficacy of PEEP in morbidly obese patients to prevent atelectasis. Twenty-three adult morbidly obese patients (body mass index >35 kg/m2) were randomly assigned to one of two groups. In the PEEP group, patients breathed 100% oxygen (5 min) with a continuous positive airway pressure of 10 cm H2O and, after the induction, mechanical ventilation via a face mask with a PEEP of 10 cm H 2O. In the control group, the same induction was applied but without continuous positive airway pressure or PEEP. Atelectasis, determined by computed tomography, and blood gas analysis were measured twice: before the induction and directly after intubation. After endotracheal intubation, patients of the control group showed an increase in the amount of atelectasis, which was much larger than in the PEEP group (10.4% ± 4.8% in control group versus 1.7% ± 1.3% in PEEP group; P <0.001). After intubation with a fraction of inspired oxygen of 1.0, Pao2 was signifi-cantly higher in the PEEP group compared with the control group (457 ± 130 mm Hg versus 315 ± 100 mm Hg, respectively; P = 0.035) We conclude that in morbidly obese patients, atelectasis formation is largely prevented by PEEP applied during the anesthetic induction and is associated with a better oxygenation.
UR - http://www.scopus.com/inward/record.url?scp=1942468851&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=1942468851&partnerID=8YFLogxK
M3 - Article
C2 - 15105237
AN - SCOPUS:1942468851
SN - 0003-2999
VL - 98
SP - 1491
EP - 1495
JO - Anesthesia and Analgesia
JF - Anesthesia and Analgesia
IS - 5
ER -