TY - JOUR
T1 - Preoperative intrathoracic lymph node staging in patients with non-small-cell lung cancer
T2 - accuracy of integrated positron emission tomography and computed tomography
AU - Billé, Andrea
AU - Pelosi, Ettore
AU - Skanjeti, Andrea
AU - Arena, Vincenzo
AU - Errico, Luca
AU - Borasio, Piero
AU - Mancini, Maurizio
AU - Ardissone, Francesco
PY - 2009/9
Y1 - 2009/9
N2 - Objective: To evaluate the accuracy of integrated positron emission tomography with 18F-fluoro-2-deoxy-d-glucose (FDG) and computed tomography (PET/CT) in preoperative intrathoracic lymph node staging in patients with non-small-cell lung cancer (NSCLC) and to ascertain the role of invasive staging in verifying positron emission tomography (PET)/computed tomography (CT) results. Methods: Retrospective, single institution study of consecutive patients with suspected or pathologically proven, potentially resectable NSCLC undergoing integrated PET/CT scanning in the same PET centre. Lymph node staging was pathologically confirmed on tissue specimens obtained at mediastinoscopy and/or thoracotomy. Statistical evaluation of PET/CT results was performed on a per-patient and per-nodal-station bases. Results: A total of 1001 nodal stations (723 mediastinal, 148 hilar and 130 intrapulmonary) were evaluated in 159 patients. Nodes were positive for malignancy in 48 (30.2%) out of 159 patients (N1 = 17; N2 = 30; N3 = 1) and 71 (7.1%) out of 1001 nodal stations (N1 = 24; N2 = 46; N3 = 1). At univariate analysis, lymph node involvement was significantly associated (p <0.05) with the following primary tumour characteristics: increasing diameter, maximum standardised uptake value >9, central location and presence of vascular invasion. PET/CT staged the disease correctly in 128 out of 159 patients (80.5%), overstaging occurred in nine patients (5.7%) and understaging in 22 patients (13.8%). The overall sensitivity, specificity, positive and negative predictive values, and accuracy of PET/CT for detecting metastatic lymph nodes were 54.2%, 91.9%, 74.3%, 82.3% and 80.5% on a per-patient basis, and 57.7%, 98.5%, 74.5%, 96.8% and 95.6% on per-nodal-station basis. With regard to N2/N3 disease, PET/CT accuracy was 84.9% and 95.3% on a per-patient basis and on per-nodal-station basis, respectively. Referring to nodal size, PET/CT sensitivity to detect malignant involvement was 32.4% (12/37) in nodes
AB - Objective: To evaluate the accuracy of integrated positron emission tomography with 18F-fluoro-2-deoxy-d-glucose (FDG) and computed tomography (PET/CT) in preoperative intrathoracic lymph node staging in patients with non-small-cell lung cancer (NSCLC) and to ascertain the role of invasive staging in verifying positron emission tomography (PET)/computed tomography (CT) results. Methods: Retrospective, single institution study of consecutive patients with suspected or pathologically proven, potentially resectable NSCLC undergoing integrated PET/CT scanning in the same PET centre. Lymph node staging was pathologically confirmed on tissue specimens obtained at mediastinoscopy and/or thoracotomy. Statistical evaluation of PET/CT results was performed on a per-patient and per-nodal-station bases. Results: A total of 1001 nodal stations (723 mediastinal, 148 hilar and 130 intrapulmonary) were evaluated in 159 patients. Nodes were positive for malignancy in 48 (30.2%) out of 159 patients (N1 = 17; N2 = 30; N3 = 1) and 71 (7.1%) out of 1001 nodal stations (N1 = 24; N2 = 46; N3 = 1). At univariate analysis, lymph node involvement was significantly associated (p <0.05) with the following primary tumour characteristics: increasing diameter, maximum standardised uptake value >9, central location and presence of vascular invasion. PET/CT staged the disease correctly in 128 out of 159 patients (80.5%), overstaging occurred in nine patients (5.7%) and understaging in 22 patients (13.8%). The overall sensitivity, specificity, positive and negative predictive values, and accuracy of PET/CT for detecting metastatic lymph nodes were 54.2%, 91.9%, 74.3%, 82.3% and 80.5% on a per-patient basis, and 57.7%, 98.5%, 74.5%, 96.8% and 95.6% on per-nodal-station basis. With regard to N2/N3 disease, PET/CT accuracy was 84.9% and 95.3% on a per-patient basis and on per-nodal-station basis, respectively. Referring to nodal size, PET/CT sensitivity to detect malignant involvement was 32.4% (12/37) in nodes
KW - Lymph node staging
KW - Non-small-cell lung cancer
KW - PET/CT
UR - http://www.scopus.com/inward/record.url?scp=68749112547&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=68749112547&partnerID=8YFLogxK
U2 - 10.1016/j.ejcts.2009.04.003
DO - 10.1016/j.ejcts.2009.04.003
M3 - Article
C2 - 19464906
AN - SCOPUS:68749112547
SN - 1010-7940
VL - 36
SP - 440
EP - 445
JO - European Journal of Cardio-thoracic Surgery
JF - European Journal of Cardio-thoracic Surgery
IS - 3
ER -