T1 - Mechanical Ventilation and Diaphragmatic Atrophy in Critically Ill Patients
T2 - An Ultrasound Study
AU - Zambon, Massimo
AU - Beccaria, Paolo
AU - Matsuno, Jun
AU - Gemma, Marco
AU - Frati, Elena
AU - Colombo, Sergio
AU - Cabrini, Luca
AU - Landoni, Giovanni
AU - Zangrillo, Alberto
PY - 2016/3/17
Y1 - 2016/3/17
N2 - OBJECTIVE:: Mechanical ventilation contributes to diaphragmatic atrophy and dysfunction, and few techniques exist to assess diaphragmatic function: the purpose of this study was to quantify diaphragm atrophy in a population of critically ill mechanically ventilated patients with ultrasound and to identify risk factors that can worsen diaphragmatic activity. DESIGN:: Prospective observational study. SETTING:: ICU of a 1,200-bed university hospital. PATIENTS:: Newly intubated adult critically ill patients. INTERVENTIONS:: Diaphragm thickness in the zone of apposition was measured daily with ultrasound, from the first day of mechanical ventilation till discharge to the main ward. MEASUREMENTS AND MAIN RESULTS:: Daily atrophy rate (ΔTdi/d) was calculated as the reduction in percentage from the previous measurement. To analyze the difference in atrophy rate (ΔTdi/d), ventilation was categorized into four classes: spontaneous breathing or continuous positive airway pressure; pressure support ventilation 5–12 cm H2O (low pressure support ventilation); pressure support ventilation greater than 12 cm H2O (high pressure support ventilation); and controlled mechanical ventilation. Multivariate analysis with ventilation support and other clinical variables was performed to identify risk factors for atrophy. Forty patients underwent a total of 153 ultrasonographic evaluations. Mean (SD) ΔTdi/d was –7.5% (12.3) during controlled mechanical ventilation, –5.3% (12.9) at high pressure support ventilation, –1.5% (10.9) at low pressure support ventilation, +2.3% (9.5) during spontaneous breathing or continuous positive airway pressure. At multivariate analysis, only the ventilation support was predictive of diaphragm atrophy rate. Pressure support predicted diaphragm thickness with coefficient –0.006 (95% CI, –0.010 to –0.002; p = 0.006). CONCLUSIONS:: In critically ill mechanically ventilated patients, there is a linear relationship between ventilator support and diaphragmatic atrophy rate.
AB - OBJECTIVE:: Mechanical ventilation contributes to diaphragmatic atrophy and dysfunction, and few techniques exist to assess diaphragmatic function: the purpose of this study was to quantify diaphragm atrophy in a population of critically ill mechanically ventilated patients with ultrasound and to identify risk factors that can worsen diaphragmatic activity. DESIGN:: Prospective observational study. SETTING:: ICU of a 1,200-bed university hospital. PATIENTS:: Newly intubated adult critically ill patients. INTERVENTIONS:: Diaphragm thickness in the zone of apposition was measured daily with ultrasound, from the first day of mechanical ventilation till discharge to the main ward. MEASUREMENTS AND MAIN RESULTS:: Daily atrophy rate (ΔTdi/d) was calculated as the reduction in percentage from the previous measurement. To analyze the difference in atrophy rate (ΔTdi/d), ventilation was categorized into four classes: spontaneous breathing or continuous positive airway pressure; pressure support ventilation 5–12 cm H2O (low pressure support ventilation); pressure support ventilation greater than 12 cm H2O (high pressure support ventilation); and controlled mechanical ventilation. Multivariate analysis with ventilation support and other clinical variables was performed to identify risk factors for atrophy. Forty patients underwent a total of 153 ultrasonographic evaluations. Mean (SD) ΔTdi/d was –7.5% (12.3) during controlled mechanical ventilation, –5.3% (12.9) at high pressure support ventilation, –1.5% (10.9) at low pressure support ventilation, +2.3% (9.5) during spontaneous breathing or continuous positive airway pressure. At multivariate analysis, only the ventilation support was predictive of diaphragm atrophy rate. Pressure support predicted diaphragm thickness with coefficient –0.006 (95% CI, –0.010 to –0.002; p = 0.006). CONCLUSIONS:: In critically ill mechanically ventilated patients, there is a linear relationship between ventilator support and diaphragmatic atrophy rate.
UR - http://www.scopus.com/inward/record.url?scp=84961219192&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84961219192&partnerID=8YFLogxK
U2 - 10.1097/CCM.0000000000001657
DO - 10.1097/CCM.0000000000001657
M3 - Article
AN - SCOPUS:84961219192
SN - 0090-3493
JO - Critical Care Medicine
JF - Critical Care Medicine
ER -