TY - JOUR
T1 - Magnetic resonance evaluation of autonomous thyroid nodules treated by percutaneous ethanol injection
AU - Sardanelli, F.
AU - Giordano, G. D.
AU - Melani, E.
AU - Parodi, R. C.
AU - Giusti, M.
AU - Garlaschi, G.
PY - 1997
Y1 - 1997
N2 - Magnetic resonance (MR) imaging was used to evaluate the effect of ultrasound-guided percutaneous ethanol injection (PEI) of autonomous thyroid nodules (ATNs). Nine patients affected with ATN (3.7-32.2 mL volume) underwent PEI (4-19 mL ethanol, subdivided in 3-6 weekly procedures). MR imaging (1.5 T) was performed before each alcoholization and 1 month after the last PEI procedure with the following parameters: T1- (550/12) and T2- weighted (2200/160) spin-echo images; 4-mm slices, 10% gap; coronal planes. A further seven patients with normal thyroid function, who had undergone PEI 6- 18 months before, underwent an MR examination with the same parameters. The signal-to-noise ratio (S/N) of ATN and extranodular gland, as well as ATN volume, were evaluated on the T2-weighted images. On T1-weighted images, ATNs appeared mostly hypointense before treatment, with hyperintense areas during treatment, and were lightly hyperintense 6-18 months after treatment. S/N on T2-weighted images: extranodular gland 3.5-9.2; ATNs, before treatment 13.2-19.7, before the last procedure 7.7-11.6, 1 month after the last procedure 5.6-10.9; previously treated ATNs, 4.3-8.2. No significant volume reduction was observed with MR 1 month after the last procedure. The MR examination time was about 15 minutes. In conclusion, the effect of PEI on ATNs can be evaluated with an MR examination that is not very time consuming.
AB - Magnetic resonance (MR) imaging was used to evaluate the effect of ultrasound-guided percutaneous ethanol injection (PEI) of autonomous thyroid nodules (ATNs). Nine patients affected with ATN (3.7-32.2 mL volume) underwent PEI (4-19 mL ethanol, subdivided in 3-6 weekly procedures). MR imaging (1.5 T) was performed before each alcoholization and 1 month after the last PEI procedure with the following parameters: T1- (550/12) and T2- weighted (2200/160) spin-echo images; 4-mm slices, 10% gap; coronal planes. A further seven patients with normal thyroid function, who had undergone PEI 6- 18 months before, underwent an MR examination with the same parameters. The signal-to-noise ratio (S/N) of ATN and extranodular gland, as well as ATN volume, were evaluated on the T2-weighted images. On T1-weighted images, ATNs appeared mostly hypointense before treatment, with hyperintense areas during treatment, and were lightly hyperintense 6-18 months after treatment. S/N on T2-weighted images: extranodular gland 3.5-9.2; ATNs, before treatment 13.2-19.7, before the last procedure 7.7-11.6, 1 month after the last procedure 5.6-10.9; previously treated ATNs, 4.3-8.2. No significant volume reduction was observed with MR 1 month after the last procedure. The MR examination time was about 15 minutes. In conclusion, the effect of PEI on ATNs can be evaluated with an MR examination that is not very time consuming.
KW - Autonomous nodules
KW - Hyperthyroidism
KW - Magnetic resonance
KW - Percutaneous ethanol injection
KW - Thyroid
KW - Thyroid nodules
UR - http://www.scopus.com/inward/record.url?scp=0031451636&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0031451636&partnerID=8YFLogxK
M3 - Article
C2 - 9440827
AN - SCOPUS:0031451636
SN - 1352-8661
VL - 5
SP - 267
EP - 274
JO - Magnetic Resonance Materials in Physics, Biology, and Medicine
JF - Magnetic Resonance Materials in Physics, Biology, and Medicine
IS - 4
ER -