T1 - Low-dose computed tomography for lung cancer screening
T2 - comparison of performance between annual and biennial screen
AU - Sverzellati, Nicola
AU - Silva, M.
AU - Calareso, G.
AU - Galeone, C.
AU - Marchianò, A.
AU - Sestini, S.
AU - Sozzi, G.
AU - Pastorino, U.
PY - 2016/2/11
Y1 - 2016/2/11
N2 - Objectives: To compare the performance metrics of two different strategies of lung cancer screening by low-dose computed tomography (LDCT), namely, annual (LDCT1) or biennial (LDCT2) screen. Methods: Recall rate, detection rate, interval cancers, sensitivity, specificity, positive and negative predictive values (PPV and NPV, respectively) were compared between LDCT1 and LDCT2 arms of the MILD trial over the first seven (T0-T6; median follow-up 7.3 years) and four rounds (T0-T3; median follow-up 7.3 years), respectively. Results: 1152 LDCT1 and 1151 LDCT2 participants underwent a total of 6893 and 4715 LDCT scans, respectively. The overall recall rate was higher in LDCT2 arm (6.97 %) than in LDCT1 arm (5.81 %) (p = 0.01), which was counterbalanced by the overall lower number of LDCT scans. No difference was observed for the overall detection rate (0.56 % in both arms). The two LDCT arms had similar specificity (99.2 % in both arms), sensitivity (73.5 %, in LDCT2 vs. 68.5 % in LDCT1, p = 0.62), PPV (42.4 %, in LDCT2, vs. 40.6 %, in LDCT1, p = 0.83) and NPV (99.8 %, in LDCT2 vs. 99.7 %, in LDCT1, p = 0.71). Conclusion: Biennial screen may save about one third of LDCT scans with similar performance indicators as compared to annual screening.Key Points: • Biennial LDCT screening may be as efficient as the annual screening.• Annual and biennial LDCT screening have similar frequency of interval lung cancers.• Biennial screening may save about one third of LDCT scans.
AB - Objectives: To compare the performance metrics of two different strategies of lung cancer screening by low-dose computed tomography (LDCT), namely, annual (LDCT1) or biennial (LDCT2) screen. Methods: Recall rate, detection rate, interval cancers, sensitivity, specificity, positive and negative predictive values (PPV and NPV, respectively) were compared between LDCT1 and LDCT2 arms of the MILD trial over the first seven (T0-T6; median follow-up 7.3 years) and four rounds (T0-T3; median follow-up 7.3 years), respectively. Results: 1152 LDCT1 and 1151 LDCT2 participants underwent a total of 6893 and 4715 LDCT scans, respectively. The overall recall rate was higher in LDCT2 arm (6.97 %) than in LDCT1 arm (5.81 %) (p = 0.01), which was counterbalanced by the overall lower number of LDCT scans. No difference was observed for the overall detection rate (0.56 % in both arms). The two LDCT arms had similar specificity (99.2 % in both arms), sensitivity (73.5 %, in LDCT2 vs. 68.5 % in LDCT1, p = 0.62), PPV (42.4 %, in LDCT2, vs. 40.6 %, in LDCT1, p = 0.83) and NPV (99.8 %, in LDCT2 vs. 99.7 %, in LDCT1, p = 0.71). Conclusion: Biennial screen may save about one third of LDCT scans with similar performance indicators as compared to annual screening.Key Points: • Biennial LDCT screening may be as efficient as the annual screening.• Annual and biennial LDCT screening have similar frequency of interval lung cancers.• Biennial screening may save about one third of LDCT scans.
KW - Biennial screening
KW - Interval cancer
KW - Low-dose computed tomography
KW - Lung cancer screening
KW - Strategy
UR - http://www.scopus.com/inward/record.url?scp=84957711236&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84957711236&partnerID=8YFLogxK
U2 - 10.1007/s00330-016-4228-3
DO - 10.1007/s00330-016-4228-3
M3 - Article
AN - SCOPUS:84957711236
SN - 0938-7994
SP - 1
EP - 9
JO - European Radiology
JF - European Radiology
ER -