TY - JOUR
T1 - Left ventricular (LV) pacing in newborns and infants
T2 - Echo assessment of LV systolic function and synchrony at 5-year follow-up
AU - Silvetti, Massimo Stefano
AU - Muzi, Giulia
AU - Unolt, Marta
AU - D'Anna, Carolina
AU - Saputo, Fabio Anselmo
AU - Di Mambro, Corrado
AU - Albanese, Sonia
AU - Ammirati, Antonio
AU - Ravà, Lucilla
AU - Drago, Fabrizio
N1 - Publisher Copyright:
© 2020 The Authors. Pacing and Clinical Electrophysiology published by Wiley Periodicals LLC
PY - 2020/6/1
Y1 - 2020/6/1
N2 - Background: Small retrospective studies reported that left ventricular (LV) pacing is likely to preserve LV function in children with isolated congenital complete atrioventricular block (CCAVB). The aim of this study was to prospectively evaluate LV contractility and synchrony in a cohort of neonates/infants at pacemaker implantation and follow-up. Methods: Patients with CCAVB who underwent LV pacing were evaluated with electrocardiogram and echocardiogram in a single-center, prospective study. Data were collected at implantation, at 1-month and every year of follow-up, up to 5 years. LV ventricular dimensions (diameters and volumes), systolic function (ejection fraction [EF] and global longitudinal strain [GLS]), and synchrony were evaluated. Data are reported as median (25th-75th centiles). Results: Twenty consecutive patients with CCAVB underwent pacemaker implantation (12 single-chamber pacemaker [VVIR] and eight dual-chamber pacemaker [DDD]) with epicardial leads: 17 on the LV apex and three on the free wall. Age at implantation was 0.3 months (1 day-4.5 months). Patients showed good clinical status, normal LV dimensions, preserved systolic function, and synchrony at 60 (30-60) months follow-up. EF increased to normal values in patients with preimplantation EF <50%. Presence of antibodies and pacing mode (DDD vs VVIR) had no impact on the outcome. Conclusions: LV pacing preserved LV systolic function and synchrony in neonates and infants with CCAVB at 5-year follow-up. LV EF improved in patients with low preimplantation EF. Pacing mode or the presence of autoantibodies did not demonstrated an impact on LV contractility and synchrony.
AB - Background: Small retrospective studies reported that left ventricular (LV) pacing is likely to preserve LV function in children with isolated congenital complete atrioventricular block (CCAVB). The aim of this study was to prospectively evaluate LV contractility and synchrony in a cohort of neonates/infants at pacemaker implantation and follow-up. Methods: Patients with CCAVB who underwent LV pacing were evaluated with electrocardiogram and echocardiogram in a single-center, prospective study. Data were collected at implantation, at 1-month and every year of follow-up, up to 5 years. LV ventricular dimensions (diameters and volumes), systolic function (ejection fraction [EF] and global longitudinal strain [GLS]), and synchrony were evaluated. Data are reported as median (25th-75th centiles). Results: Twenty consecutive patients with CCAVB underwent pacemaker implantation (12 single-chamber pacemaker [VVIR] and eight dual-chamber pacemaker [DDD]) with epicardial leads: 17 on the LV apex and three on the free wall. Age at implantation was 0.3 months (1 day-4.5 months). Patients showed good clinical status, normal LV dimensions, preserved systolic function, and synchrony at 60 (30-60) months follow-up. EF increased to normal values in patients with preimplantation EF <50%. Presence of antibodies and pacing mode (DDD vs VVIR) had no impact on the outcome. Conclusions: LV pacing preserved LV systolic function and synchrony in neonates and infants with CCAVB at 5-year follow-up. LV EF improved in patients with low preimplantation EF. Pacing mode or the presence of autoantibodies did not demonstrated an impact on LV contractility and synchrony.
KW - alternative pacing sites
KW - cardiac pacing
KW - children
KW - congenital atrioventricular block
KW - heart failure
UR - http://www.scopus.com/inward/record.url?scp=85083765836&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85083765836&partnerID=8YFLogxK
U2 - 10.1111/pace.13908
DO - 10.1111/pace.13908
M3 - Article
C2 - 32233121
AN - SCOPUS:85083765836
SN - 0147-8389
VL - 43
SP - 535
EP - 541
JO - PACE - Pacing and Clinical Electrophysiology
JF - PACE - Pacing and Clinical Electrophysiology
IS - 6
ER -