TY - JOUR
T1 - Interfraction prostate displacement during image-guided radiotherapy using intraprostatic fiducial markers and a cone-beam computed tomography system
T2 - A volumetric off-line analysis in relation to the variations of rectal and bladder volumes
AU - Ingrosso, Gianluca
AU - Miceli, Roberto
AU - Ponti, Elisabetta
AU - Lancia, Andrea
AU - Di Cristino, Daniela
AU - De Pasquale, Francesco
AU - Bove, Pierluigi
AU - Santoni, Riccardo
PY - 2019/3/1
Y1 - 2019/3/1
N2 - Purpose: Prostate motion during the radiotherapy course is an important issue. This study investigated the inter-fraction prostate motion in controlled rectal filling condition. Methods: 10 prostate cancer patients underwent image-guided radiotherapy (IGRT) using a cone-beam computed tomography (CBCT) system, after the insertion of fiducial markers (FMs). The planning CT was the reference CT (CTref) used to estimate the reference intermarker distances, and CBCTs were used for off-line comparison with CTref. We evaluated the influence of rectal and bladder volume on prostate shifts. We calculated the required planning target volume (PTV) margins in this patient population. Results: 120 CBCTs were analyzed. Mean prostate displacements (± SD) along the 3 axes (x, y, z) averaged over the 10 patients, were: 0.90 ± 0.84 mm in x, 0.00 ± 2.07 mm in y, -0.80 ± 1.28 mm in z. There is a statistically significant anti-correlation between prostate displacements and: bladder volume variations (P < 0.001) in the y-axis, and rectal volume variations (P < 0.05) in the z-axis. PTV margins obtained for the directions x, y and z are respectively 2.5, 5.6 and 3.9 mm. Conclusion: IGRT in reproducible empty rectum condition allow a high reduction of daily treatment uncertainties.
AB - Purpose: Prostate motion during the radiotherapy course is an important issue. This study investigated the inter-fraction prostate motion in controlled rectal filling condition. Methods: 10 prostate cancer patients underwent image-guided radiotherapy (IGRT) using a cone-beam computed tomography (CBCT) system, after the insertion of fiducial markers (FMs). The planning CT was the reference CT (CTref) used to estimate the reference intermarker distances, and CBCTs were used for off-line comparison with CTref. We evaluated the influence of rectal and bladder volume on prostate shifts. We calculated the required planning target volume (PTV) margins in this patient population. Results: 120 CBCTs were analyzed. Mean prostate displacements (± SD) along the 3 axes (x, y, z) averaged over the 10 patients, were: 0.90 ± 0.84 mm in x, 0.00 ± 2.07 mm in y, -0.80 ± 1.28 mm in z. There is a statistically significant anti-correlation between prostate displacements and: bladder volume variations (P < 0.001) in the y-axis, and rectal volume variations (P < 0.05) in the z-axis. PTV margins obtained for the directions x, y and z are respectively 2.5, 5.6 and 3.9 mm. Conclusion: IGRT in reproducible empty rectum condition allow a high reduction of daily treatment uncertainties.
KW - Image-guided radiotherapy
KW - inter-fraction displacement
KW - prostate cancer
KW - volumetric off-line analysis
UR - http://www.scopus.com/inward/record.url?scp=85063495152&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85063495152&partnerID=8YFLogxK
U2 - 10.4103/jcrt.JCRT_463_17
DO - 10.4103/jcrt.JCRT_463_17
M3 - Article
C2 - 30900624
AN - SCOPUS:85063495152
SN - 0973-1482
VL - 15
SP - S69-S75
JO - Journal of Cancer Research and Therapeutics
JF - Journal of Cancer Research and Therapeutics
IS - 8
ER -