T1 - Flow cytometric detection and quantitative analysis of the GM-CSF receptor in human granulocytes and comparison with the radioligand binding assay
AU - Stacchini, Alessandra
AU - Fubini, Lidia
AU - Aglietta, Massimo
PY - 1996/8/1
Y1 - 1996/8/1
N2 - A flow cytometric method to quantify the granulocyte-macrophage colony-stimulating factor receptor (GM-CSFr) on human cells is described. The number of GM-CSFr binding sites on human neutrophils was assessed by using different bead standards. Results were compared with those from conventional receptor quantification, which was performed by using the radioligand binding assay. A high degree of correlation was found between the two methods, although quantitative evaluation of GM-CSFr expression on neutrophils performed by flow cytometry revealed a somewhat higher number of receptor molecules per cell than with that determined by Scatchard analysis. By the flow quantitative approach, we measured the GM-CSFr on mobilized CD34-positive cells and obtained results similar to those of previously published data. Our data suggest that flow cytometric analysis is a simple and reproducible method to detect and quantify the presence of GM-CSFr per cell, thus allowing the study of receptor expression on different populations selected by gating on the basis of the scatter parameters and surface markers. This assay offers the possibility to quantify the presence of GM-CSFr on different subsets of normal and pathological cells even if samples are too small (such as CD34-positive progenitor cells) for measurement with the radioligand binding assay.
AB - A flow cytometric method to quantify the granulocyte-macrophage colony-stimulating factor receptor (GM-CSFr) on human cells is described. The number of GM-CSFr binding sites on human neutrophils was assessed by using different bead standards. Results were compared with those from conventional receptor quantification, which was performed by using the radioligand binding assay. A high degree of correlation was found between the two methods, although quantitative evaluation of GM-CSFr expression on neutrophils performed by flow cytometry revealed a somewhat higher number of receptor molecules per cell than with that determined by Scatchard analysis. By the flow quantitative approach, we measured the GM-CSFr on mobilized CD34-positive cells and obtained results similar to those of previously published data. Our data suggest that flow cytometric analysis is a simple and reproducible method to detect and quantify the presence of GM-CSFr per cell, thus allowing the study of receptor expression on different populations selected by gating on the basis of the scatter parameters and surface markers. This assay offers the possibility to quantify the presence of GM-CSFr on different subsets of normal and pathological cells even if samples are too small (such as CD34-positive progenitor cells) for measurement with the radioligand binding assay.
KW - GM-CSFr quantification
KW - Microbeads
KW - Radioligand binding
UR - http://www.scopus.com/inward/record.url?scp=0029819190&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0029819190&partnerID=8YFLogxK
U2 - 10.1002/(SICI)1097-0320(19960801)24:4<374::AID-CYTO9>3.0.CO;2-F
DO - 10.1002/(SICI)1097-0320(19960801)24:4<374::AID-CYTO9>3.0.CO;2-F
M3 - Article
C2 - 8866222
AN - SCOPUS:0029819190
SN - 1552-4949
VL - 24
SP - 374
EP - 381
JO - Cytometry Part B - Clinical Cytometry
JF - Cytometry Part B - Clinical Cytometry
IS - 4
ER -