T1 - Detection of urinary tract stones at low-radiation-dose CT with z-axis automatic tube current modulation
T2 - Phantom and clinical studies
AU - Kalra, Mannudeep K.
AU - Maher, Michael M.
AU - D'Souza, Roy V.
AU - Rizzo, Stefania
AU - Halpern, Elkan F.
AU - Blake, Michael A.
AU - Saini, Sanjay
PY - 2005/5
Y1 - 2005/5
N2 - PURPOSE: To evaluate depiction of urinary tract calculi at computed tomography (CT) with a z-axis modulation technique at various noise indexes to reduce radiation dose and preserve image quality. MATERIALS AND METHODS: Sixteen radiopaque kidney stones (2.5-19.2 mm in diameter) were embedded in the collecting systems of two bovine kidneys immersed in a water bath. A kidney phantom was made by placing the kidneys in an elliptical Plexiglas phantom (32 x 20 x 20 cm) filled with physiologic saline. The phantom was scanned at 16-detector row CT with a fixed tube current (300 mA) and z-axis modulation at noise indexes of 14, 20, 25, 35, and 50; remaining imaging parameters were held constant. Two abdominal radiologists reviewed images from most to least noisy. Images were evaluated for presence of stones and size, site, and attenuation value of each stone. Readers also graded conspicuity and margins of each stone on a five-point scale. In addition, follow-up studies of 22 patients (mean age, 46 years; range, 26-57 years; male-female ratio, 14:8) with kidney and ureteral stones who underwent CT with z-axis modulation (noise index, 14 and 20) were evaluated in the same manner. Statistical analysis was performed with the Student t test, Wilcoxon signed rank test, and κ test of interobserver agreement. Institutional review board approval was obtained, and informed consent was not needed. RESULTS: In the phantom study, all 16 stones were identified on images obtained with a fixed tube current and z-axis modulation at noise indexes of 14, 20, and 25 (with a reduction in radiation dose of up to 77% compared with that of fixed tube current scanning). Three stones ( .05). CONCLUSION: Kidney stones (≤2.5 mm) can be adequately depicted with the z-axis modulation technique, with a 56%-77% reduction in radiation dose. In patients with urinary tract stones, the technique results in a 43%-66% reduction in radiation dose at noise indexes of 14 and 20 without compromising stone depiction.
AB - PURPOSE: To evaluate depiction of urinary tract calculi at computed tomography (CT) with a z-axis modulation technique at various noise indexes to reduce radiation dose and preserve image quality. MATERIALS AND METHODS: Sixteen radiopaque kidney stones (2.5-19.2 mm in diameter) were embedded in the collecting systems of two bovine kidneys immersed in a water bath. A kidney phantom was made by placing the kidneys in an elliptical Plexiglas phantom (32 x 20 x 20 cm) filled with physiologic saline. The phantom was scanned at 16-detector row CT with a fixed tube current (300 mA) and z-axis modulation at noise indexes of 14, 20, 25, 35, and 50; remaining imaging parameters were held constant. Two abdominal radiologists reviewed images from most to least noisy. Images were evaluated for presence of stones and size, site, and attenuation value of each stone. Readers also graded conspicuity and margins of each stone on a five-point scale. In addition, follow-up studies of 22 patients (mean age, 46 years; range, 26-57 years; male-female ratio, 14:8) with kidney and ureteral stones who underwent CT with z-axis modulation (noise index, 14 and 20) were evaluated in the same manner. Statistical analysis was performed with the Student t test, Wilcoxon signed rank test, and κ test of interobserver agreement. Institutional review board approval was obtained, and informed consent was not needed. RESULTS: In the phantom study, all 16 stones were identified on images obtained with a fixed tube current and z-axis modulation at noise indexes of 14, 20, and 25 (with a reduction in radiation dose of up to 77% compared with that of fixed tube current scanning). Three stones ( .05). CONCLUSION: Kidney stones (≤2.5 mm) can be adequately depicted with the z-axis modulation technique, with a 56%-77% reduction in radiation dose. In patients with urinary tract stones, the technique results in a 43%-66% reduction in radiation dose at noise indexes of 14 and 20 without compromising stone depiction.
UR - http://www.scopus.com/inward/record.url?scp=17644389579&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=17644389579&partnerID=8YFLogxK
U2 - 10.1148/radiol.2352040331
DO - 10.1148/radiol.2352040331
M3 - Article
C2 - 15770037
AN - SCOPUS:17644389579
SN - 0033-8419
VL - 235
SP - 523
EP - 529
JO - Radiology
JF - Radiology
IS - 2
ER -