Abstract
Estimating the main axis of rotation (AoR) of a human joint represents an important issue in biomechanics. This study compared three formal methods used to estimate functional AoR, namely a cylindrical fitting method, a mean helical axis transformation, and a symmetrical axis approach. These methods were tested on 106 subjects undergoing navigated total knee arthroplasty. AoR orientation in 3D and in the frontal and coronal planes provided by each method was compared to the transepicondylar axis direction. Although all the methods resulted effective, significant differences were identified among them, relatively to the orientation in 3D and in the frontal plane projection. This was probably due to the presence of secondary rotations during the first degrees of knee flexion.
Original language | English |
---|---|
Pages (from-to) | 484-492 |
Number of pages | 9 |
Journal | Computer Methods in Biomechanics and Biomedical Engineering |
Volume | 19 |
Issue number | 5 |
DOIs | |
Publication status | Published - Apr 3 2016 |
Keywords
- cylindrical fitting method
- functional axis
- knee kinematics
- mean helical axis
- navigated TKA
- symmetrical axis approach
ASJC Scopus subject areas
- Bioengineering
- Biomedical Engineering
- Computer Science Applications