T1 - Comparison of the Performance of Two Different Spectral-Domain Optical Coherence Tomography Angiography Devices in Clinical Practice
AU - De Vitis, Luigi Antonio
AU - Benatti, Lucia
AU - Tomasso, Livia
AU - Baldin, Giovanni
AU - Carnevali, Adriano
AU - Querques, Lea
AU - Querques, Giuseppe
AU - Bandello, Francesco
PY - 2016/7/12
Y1 - 2016/7/12
N2 - Purpose: To compare the performance of two different spectral-domain optical coherence tomography angiography (OCTA) devices in clinical practice by evaluating examination execution time and the number of motion artifacts per image. Methods: Seventy-six patients affected by different ocular diseases and 13 healthy subjects consecutively underwent assessments by two different OCTA devices: AngioPlex (Zeiss Meditec, Inc., Dublin, Calif., USA) and AngioVue (OptoVue, Inc., Fremont, Calif., USA). Two different operators (L.A.D.V. and L.B.) measured execution times, excluded low-quality images, and counted the number of motion artifacts per image. Results: The mean execution time was shorter with AngioPlex than with AngioVue for all subjects (3 min 32 s ± 1 min 45 s vs. 4 min 35 s ± 1 min 11 s; p <0.0001), for the healthy subjects (2 min 31 s ± 45 s vs. 4 min 1 s ± 53 s; p = 0.003), and for the patients (3 min 44 s ± 1 min 48 s vs. 4 min 42 s ± 1 min 13 s; p <0.0001). The percentages of available images, low-signal-strength images, and images impossible to analyze of the total acquired images obtained using AngioPlex or AngioVue were 85, 6, and 9% and 56, 29, and 15%, respectively. The mean number of motion artifacts was significantly lower in images obtained using AngioPlex than in images obtained using AngioVue for all patients (6.5 ± 5.9 vs. 12.6 ± 8.5; p <0.0001), for the healthy subjects (6.5 ± 4.6 vs. 10.9 ± 7.9; p = 0.0009), and for the patients (6.6 ± 6.3 vs. 13.1 ± 8.7; p <0.0001). There was no correlation between the number of artifacts and execution time or patients' age. Conclusion: AngioPlex and AngioVue are useful devices in clinical practice. AngioPlex requires a shorter execution time and provides a higher number of images available for analysis with fewer motion artifacts.
AB - Purpose: To compare the performance of two different spectral-domain optical coherence tomography angiography (OCTA) devices in clinical practice by evaluating examination execution time and the number of motion artifacts per image. Methods: Seventy-six patients affected by different ocular diseases and 13 healthy subjects consecutively underwent assessments by two different OCTA devices: AngioPlex (Zeiss Meditec, Inc., Dublin, Calif., USA) and AngioVue (OptoVue, Inc., Fremont, Calif., USA). Two different operators (L.A.D.V. and L.B.) measured execution times, excluded low-quality images, and counted the number of motion artifacts per image. Results: The mean execution time was shorter with AngioPlex than with AngioVue for all subjects (3 min 32 s ± 1 min 45 s vs. 4 min 35 s ± 1 min 11 s; p <0.0001), for the healthy subjects (2 min 31 s ± 45 s vs. 4 min 1 s ± 53 s; p = 0.003), and for the patients (3 min 44 s ± 1 min 48 s vs. 4 min 42 s ± 1 min 13 s; p <0.0001). The percentages of available images, low-signal-strength images, and images impossible to analyze of the total acquired images obtained using AngioPlex or AngioVue were 85, 6, and 9% and 56, 29, and 15%, respectively. The mean number of motion artifacts was significantly lower in images obtained using AngioPlex than in images obtained using AngioVue for all patients (6.5 ± 5.9 vs. 12.6 ± 8.5; p <0.0001), for the healthy subjects (6.5 ± 4.6 vs. 10.9 ± 7.9; p = 0.0009), and for the patients (6.6 ± 6.3 vs. 13.1 ± 8.7; p <0.0001). There was no correlation between the number of artifacts and execution time or patients' age. Conclusion: AngioPlex and AngioVue are useful devices in clinical practice. AngioPlex requires a shorter execution time and provides a higher number of images available for analysis with fewer motion artifacts.
KW - AngioPlex
KW - AngioVue
KW - AVANTI™
KW - CIRRUS™
KW - Execution time
KW - Eye-tracking
KW - Macula
KW - Motion artifacts
KW - Optical coherence tomography angiography
KW - Spectral-domain optical coherence tomography
UR - http://www.scopus.com/inward/record.url?scp=84978488463&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84978488463&partnerID=8YFLogxK
U2 - 10.1159/000447094
DO - 10.1159/000447094
M3 - Article
AN - SCOPUS:84978488463
SN - 0030-3747
JO - Ophthalmic Research
JF - Ophthalmic Research
ER -