TY - JOUR
T1 - Comparison of image processing techniques for nonviable tissue quantification in late gadolinium enhancement cardiac magnetic resonance images
AU - Carminati, M. Chiara
AU - Boniotti, Cinzia
AU - Fusini, Laura
AU - Andreini, Daniele
AU - Pontone, Gianluca
AU - Pepi, Mauro
AU - Caiani, Enrico G.
PY - 2016
Y1 - 2016
N2 - Purpose: The aim of this study was to compare the performance of quantitative methods, either semiautomated or automated, for left ventricular (LV) nonviable tissue analysis from cardiac magnetic resonance late gadolinium enhancement (CMR-LGE) images. Materials and Methods: The investigated segmentation techniques were: (i) n-standard deviations thresholding; (ii) full width at half maximum thresholding; (iii) Gaussian mixture model classification; and (iv) fuzzy c-means clustering. These algorithms were applied either in each short axis slice (single-slice approach) or globally considering the entire short-axis stack covering the LV (global approach). CMR-LGE images from 20 patients with ischemic cardiomyopathy were retrospectively selected, and results from each technique were assessed against manual tracing. Results: All methods provided comparable performance in terms of accuracy in scar detection, computation of local transmurality, and high correlation in scar mass compared with the manual technique. In general, no significant difference between single-slice and global approach was noted. The reproducibility of manual and investigated techniques was confirmed in all cases with slightly lower results for the nSD approach. Conclusions: Automated techniques resulted in accurate and reproducible evaluation of LV scars from CMR-LGE in ischemic patients with performance similar to the manual technique. Their application could minimize user interaction and computational time, even when compared with semiautomated approaches.
AB - Purpose: The aim of this study was to compare the performance of quantitative methods, either semiautomated or automated, for left ventricular (LV) nonviable tissue analysis from cardiac magnetic resonance late gadolinium enhancement (CMR-LGE) images. Materials and Methods: The investigated segmentation techniques were: (i) n-standard deviations thresholding; (ii) full width at half maximum thresholding; (iii) Gaussian mixture model classification; and (iv) fuzzy c-means clustering. These algorithms were applied either in each short axis slice (single-slice approach) or globally considering the entire short-axis stack covering the LV (global approach). CMR-LGE images from 20 patients with ischemic cardiomyopathy were retrospectively selected, and results from each technique were assessed against manual tracing. Results: All methods provided comparable performance in terms of accuracy in scar detection, computation of local transmurality, and high correlation in scar mass compared with the manual technique. In general, no significant difference between single-slice and global approach was noted. The reproducibility of manual and investigated techniques was confirmed in all cases with slightly lower results for the nSD approach. Conclusions: Automated techniques resulted in accurate and reproducible evaluation of LV scars from CMR-LGE in ischemic patients with performance similar to the manual technique. Their application could minimize user interaction and computational time, even when compared with semiautomated approaches.
KW - Cardiac imaging techniques
KW - Computerassisted
KW - Image processing
KW - Magnetic resonance imaging
KW - Myocardial infarction
UR - http://www.scopus.com/inward/record.url?scp=84962091346&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84962091346&partnerID=8YFLogxK
U2 - 10.1097/RTI.0000000000000206
DO - 10.1097/RTI.0000000000000206
M3 - Article
AN - SCOPUS:84962091346
SN - 0883-5993
VL - 31
SP - 168
EP - 176
JO - Journal of Thoracic Imaging
JF - Journal of Thoracic Imaging
IS - 3
ER -