TY - JOUR
T1 - Comparison of four methods to simulate swelling in poroelastic finite element models of intervertebral discs
AU - Galbusera, Fabio
AU - Schmidt, Hendrik
AU - Noailly, Jérôme
AU - Malandrino, Andrea
AU - Lacroix, Damien
AU - Wilke, Hans Joachim
AU - Shirazi-Adl, Aboulfazl
PY - 2011/10
Y1 - 2011/10
N2 - Osmotic phenomena influence the intervertebral disc biomechanics. Their simulation is challenging and can be undertaken at different levels of complexity. Four distinct approaches to simulate the osmotic behaviour of the intervertebral disc (a fixed boundary pore pressure model, a fixed osmotic pressure gradient model in the whole disc or only in the nucleus pulposus, and a swelling model with strain-dependent osmotic pressure) were analysed. Predictions were compared using a 3D poroelastic finite element model of a L4-L5 spinal unit under three different loading conditions: free swelling for 8 h and two daily loading cycles: (i) 200 N compression for 8 h followed by 500 N compression for 16 h; (ii) 500 N for 8 h followed by 1000 N for 16 h. Overall, all swelling models calculated comparable results, with differences decreasing under greater loads. Results predicted with the fixed boundary pore pressure and the fixed osmotic pressure in the whole disc models were nearly identical. The boundary pore pressure model, however, cannot simulate differential osmotic pressures in disc regions. The swelling model offered the best potential to provide more accurate results, conditional upon availability of reliable values for the required coefficients and material properties. Possible fields of application include mechanobiology investigations and crack opening and propagation. However, the other approaches are a good compromise between the ease of implementation and the reliability of results, especially when considering higher loads or when the focus is on global results such as spinal kinematics.
AB - Osmotic phenomena influence the intervertebral disc biomechanics. Their simulation is challenging and can be undertaken at different levels of complexity. Four distinct approaches to simulate the osmotic behaviour of the intervertebral disc (a fixed boundary pore pressure model, a fixed osmotic pressure gradient model in the whole disc or only in the nucleus pulposus, and a swelling model with strain-dependent osmotic pressure) were analysed. Predictions were compared using a 3D poroelastic finite element model of a L4-L5 spinal unit under three different loading conditions: free swelling for 8 h and two daily loading cycles: (i) 200 N compression for 8 h followed by 500 N compression for 16 h; (ii) 500 N for 8 h followed by 1000 N for 16 h. Overall, all swelling models calculated comparable results, with differences decreasing under greater loads. Results predicted with the fixed boundary pore pressure and the fixed osmotic pressure in the whole disc models were nearly identical. The boundary pore pressure model, however, cannot simulate differential osmotic pressures in disc regions. The swelling model offered the best potential to provide more accurate results, conditional upon availability of reliable values for the required coefficients and material properties. Possible fields of application include mechanobiology investigations and crack opening and propagation. However, the other approaches are a good compromise between the ease of implementation and the reliability of results, especially when considering higher loads or when the focus is on global results such as spinal kinematics.
KW - Boundary pore pressure
KW - Finite element
KW - Intervertebral disc
KW - Osmotic pressure
KW - Poroelasticity
KW - Swelling
UR - http://www.scopus.com/inward/record.url?scp=79960557691&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=79960557691&partnerID=8YFLogxK
U2 - 10.1016/j.jmbbm.2011.04.008
DO - 10.1016/j.jmbbm.2011.04.008
M3 - Article
C2 - 21783132
AN - SCOPUS:79960557691
SN - 1751-6161
VL - 4
SP - 1234
EP - 1241
JO - Journal of the Mechanical Behavior of Biomedical Materials
JF - Journal of the Mechanical Behavior of Biomedical Materials
IS - 7
ER -