T1 - CardioSEAL/STARflex versus Amplatzer devices for percutaneous closure of small to moderate (up to 18 mm) atrial septal defects
AU - Butera, Gianfranco
AU - Carminati, Mario
AU - Chessa, Massimo
AU - Delogu, Angelica
AU - Drago, Manuela
AU - Piazza, Luciane
AU - Giamberti, Alessandro
AU - Frigiola, Alessandro
PY - 2004/9
Y1 - 2004/9
N2 - Background The Amplatzer septal occluder (ASO) allows the percutaneous closure of small to very large atrial septal defects (ASDs). The CardioSEAL/STARflex (CS/SF) can be used only for closure of small to moderate ASDs (stretch size up to 18 mm). These 2 devices are widely used in clinical practice. Therefore, a comparison of their use in the closure of small to moderate ASDs is needed. Methods From December 1996 to September 2002, 274 consecutive patients (mean age 20.3 ± 17 years) underwent percutaneous closure of small to moderate ostium secundum ASDs. The CS/SF device was used in 121 patients, and the ASO was used in 153. Results There were no differences in age, sex ratio, or pulmonary/systemic flow ratio. Stretch size of the defect was higher in the ASO group (13.6 ± 3.5 mm vs 15.5 ± 3.2 mm, P <.001). Procedure time and fluoroscopy time were shorter in patients treated with the ASO (61 ± 21 vs 75 ± 32 min, P <.0003, and 11.6 ± 9 vs 23.8 ± 17.4 min, P <.0001, respectively). Residual shunt at procedure and discharge was significantly more frequent in the CS/SF group (P <.0001). There were no differences in the complication rate for the 2 groups (CS/SF 4/121 vs ASO 6/153). Length of follow-up was longer in the CS/SF group (24 ± 14 vs 16 ± 9 months, P = .0001). Residual shunting was significantly more frequent in the CS/SF group during follow-up, while closure rate reached 100% after 1 month in ASO group. Conclusions The 2 devices are clinically safe and effective in ASD closure. However, percutaneous closure of small to moderate ASDs with ASO is quicker and provides an higher rate of complete occlusion.
AB - Background The Amplatzer septal occluder (ASO) allows the percutaneous closure of small to very large atrial septal defects (ASDs). The CardioSEAL/STARflex (CS/SF) can be used only for closure of small to moderate ASDs (stretch size up to 18 mm). These 2 devices are widely used in clinical practice. Therefore, a comparison of their use in the closure of small to moderate ASDs is needed. Methods From December 1996 to September 2002, 274 consecutive patients (mean age 20.3 ± 17 years) underwent percutaneous closure of small to moderate ostium secundum ASDs. The CS/SF device was used in 121 patients, and the ASO was used in 153. Results There were no differences in age, sex ratio, or pulmonary/systemic flow ratio. Stretch size of the defect was higher in the ASO group (13.6 ± 3.5 mm vs 15.5 ± 3.2 mm, P <.001). Procedure time and fluoroscopy time were shorter in patients treated with the ASO (61 ± 21 vs 75 ± 32 min, P <.0003, and 11.6 ± 9 vs 23.8 ± 17.4 min, P <.0001, respectively). Residual shunt at procedure and discharge was significantly more frequent in the CS/SF group (P <.0001). There were no differences in the complication rate for the 2 groups (CS/SF 4/121 vs ASO 6/153). Length of follow-up was longer in the CS/SF group (24 ± 14 vs 16 ± 9 months, P = .0001). Residual shunting was significantly more frequent in the CS/SF group during follow-up, while closure rate reached 100% after 1 month in ASO group. Conclusions The 2 devices are clinically safe and effective in ASD closure. However, percutaneous closure of small to moderate ASDs with ASO is quicker and provides an higher rate of complete occlusion.
UR - http://www.scopus.com/inward/record.url?scp=4644367094&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=4644367094&partnerID=8YFLogxK
U2 - 10.1016/j.ahj.2004.03.013
DO - 10.1016/j.ahj.2004.03.013
M3 - Article
C2 - 15389240
AN - SCOPUS:4644367094
SN - 0002-8703
VL - 148
SP - 507
EP - 510
JO - American Heart Journal
JF - American Heart Journal
IS - 3
ER -