TY - JOUR
T1 - Bipolar radiofrequency ablation for ventricular tachycardias originating from the interventricular septum
T2 - Safety and efficacy in a pilot cohort study
AU - Della Bella, Paolo
AU - Peretto, Giovanni
AU - Paglino, Gabriele
AU - Bisceglia, Caterina
AU - Radinovic, Andrea
AU - Sala, Simone
AU - Baratto, Francesca
AU - Limite, Luca Rosario
AU - Cireddu, Manuela
AU - Marzi, Alessandra
AU - D'Angelo, Giuseppe
AU - Vergara, Pasquale
AU - Gulletta, Simone
AU - Mazzone, Patrizio
AU - Frontera, Antonio
N1 - Funding Information:
Funding sources: The authors have no funding sources to disclose.
Publisher Copyright:
© 2020 Heart Rhythm Society
Copyright:
Copyright 2020 Elsevier B.V., All rights reserved.
PY - 2020/12
Y1 - 2020/12
N2 - Background: Interest has grown in recent years in bipolar radiofrequency ablation (B-RFA). However, indications and outcome in patients with ventricular tachycardia (VT) are still to be defined. Objective: The purpose of this study was to describe patient selection, safety and effectiveness of B-RFA, in a pilot cohort study of patients with nonischemic dilated cardiomyopathy (NIDCM) and drug-refractory VT. Methods: We enrolled 21 patients with NIDCM (mean age 66±10 years; 18/21 (86%) men; left ventricular ejection fraction 35%±14%; 100% redo procedures) scheduled for a B-RFA procedure because of drug-refractory VT of suspected septal (interventricular septum [IVS]) origin. After electroanatomic mapping by using the CARTO®3 system, B-RFA was performed in all patients. Short- and long-term outcomes, including procedural success, major complications, and occurrence of major ventricular arrhythmias (MVAs), were evaluated at 25±8 months of follow-up (FU). Results: Endocardial mapping showed IVS scar in all patients and extra-IVS in 7 patients (33%). B-RFA was performed at an average power of 33 W, for 60–90 seconds, over a 4.1 cm2 area, with 13±3 mm distance between catheters tips. The impedance drop was 27±4 Ω. The primary end point of noninducibility of the target clinical VT was obtained in 20 patients (95%). During FU, MVAs were documented in 7 patients (33%). FU MVAs occurred in all (100%) patients with extra-IVS localizations (7 of 7) or inflammatory nonischemic cardiomyopathy etiology (2 of 2). IVS thinning (tip-to-tip catheter distance < 5 mm) represented the only anatomical limitation to B-RFA. Conclusion: B-RFA is feasible in patients with NIDCM and drug-refractory VT of septal origin. Extra-IVS substrate and inflammatory NIDCM etiology were associated with an adverse outcome.
AB - Background: Interest has grown in recent years in bipolar radiofrequency ablation (B-RFA). However, indications and outcome in patients with ventricular tachycardia (VT) are still to be defined. Objective: The purpose of this study was to describe patient selection, safety and effectiveness of B-RFA, in a pilot cohort study of patients with nonischemic dilated cardiomyopathy (NIDCM) and drug-refractory VT. Methods: We enrolled 21 patients with NIDCM (mean age 66±10 years; 18/21 (86%) men; left ventricular ejection fraction 35%±14%; 100% redo procedures) scheduled for a B-RFA procedure because of drug-refractory VT of suspected septal (interventricular septum [IVS]) origin. After electroanatomic mapping by using the CARTO®3 system, B-RFA was performed in all patients. Short- and long-term outcomes, including procedural success, major complications, and occurrence of major ventricular arrhythmias (MVAs), were evaluated at 25±8 months of follow-up (FU). Results: Endocardial mapping showed IVS scar in all patients and extra-IVS in 7 patients (33%). B-RFA was performed at an average power of 33 W, for 60–90 seconds, over a 4.1 cm2 area, with 13±3 mm distance between catheters tips. The impedance drop was 27±4 Ω. The primary end point of noninducibility of the target clinical VT was obtained in 20 patients (95%). During FU, MVAs were documented in 7 patients (33%). FU MVAs occurred in all (100%) patients with extra-IVS localizations (7 of 7) or inflammatory nonischemic cardiomyopathy etiology (2 of 2). IVS thinning (tip-to-tip catheter distance < 5 mm) represented the only anatomical limitation to B-RFA. Conclusion: B-RFA is feasible in patients with NIDCM and drug-refractory VT of septal origin. Extra-IVS substrate and inflammatory NIDCM etiology were associated with an adverse outcome.
KW - Bipolar
KW - Interventricular septum
KW - Nonischemic cardiomyopathy
KW - RF ablation
KW - Ventricular tachycardia
UR - http://www.scopus.com/inward/record.url?scp=85090061857&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85090061857&partnerID=8YFLogxK
U2 - 10.1016/j.hrthm.2020.06.025
DO - 10.1016/j.hrthm.2020.06.025
M3 - Article
C2 - 32599177
AN - SCOPUS:85090061857
SN - 1547-5271
VL - 17
SP - 2111
EP - 2118
JO - Heart Rhythm
JF - Heart Rhythm
IS - 12
ER -