TY - JOUR
T1 - Baseline reproducibility of B-mode ultrasonic measurement of carotid artery intima-media thickness
T2 - The European Lacidipine Study on Atherosclerosis (ELSA)
AU - Tang, Rong
AU - Hennig, Michael
AU - Thomasson, Barbara
AU - Scherz, Renate
AU - Ravinetto, Raffaella
AU - Catalini, Roberto
AU - Rubba, Paolo
AU - Zanchetti, Alberto
AU - Bond, M. Gene
PY - 2000
Y1 - 2000
N2 - Background and objective. The European Lacidipine Study of Atherosclerosis (ELSA) is a prospective, randomized, double-blind, multi-national interventional trial to determine the effect of four-year treatment using the calcium antagonist lacidipine versus the β-blocker atenolol on the progression of carotid atherosclerosis in 2259 asymptomatic hypertensive patients. B-mode ultrasound is used to measure the primary and secondary endpoints including the mean maximum intima-media thickness (IMT) of the carotid bifurcations and the common carotid arteries (CBM(max)), the mean maximum IMT of 12 standard carotid sites (M(max)) and the overall maximum IMT (T(max)). This paper reports the cross-sectional reproducibility of ultrasound measurements at baseline. Method. To evaluate measurement reliability, each patient is scanned twice at baseline and again at four annual visits, with 80% of the replicate scans performed by the same sonographer and 20% by a different sonographer; 50% of the replicate scans are read by the same reader and the other 50% by different readers. Results. The overall coefficient of reliability (R) was 0.859 for CBM(max), 0.872 for M(max) and 0.794 for T(max). The reliability for CBM(max) was stable during the 1-year baseline period (R = 0.848 to 0.953) and was uniform among the 23 field centres (R = 0.798 to 0.926). Intra- and inter-reader reliability were 0.915 and 0.872 respectively, and intra-sonographer reliability was 0.866. Conclusion. The results demonstrate that by implementing standardized protocols and strict quality control procedures, highly reliable ultrasonic measurements of carotid artery IMT can be achieved in large multi-national trials. (C) Lippincott Williams and Wilkins.
AB - Background and objective. The European Lacidipine Study of Atherosclerosis (ELSA) is a prospective, randomized, double-blind, multi-national interventional trial to determine the effect of four-year treatment using the calcium antagonist lacidipine versus the β-blocker atenolol on the progression of carotid atherosclerosis in 2259 asymptomatic hypertensive patients. B-mode ultrasound is used to measure the primary and secondary endpoints including the mean maximum intima-media thickness (IMT) of the carotid bifurcations and the common carotid arteries (CBM(max)), the mean maximum IMT of 12 standard carotid sites (M(max)) and the overall maximum IMT (T(max)). This paper reports the cross-sectional reproducibility of ultrasound measurements at baseline. Method. To evaluate measurement reliability, each patient is scanned twice at baseline and again at four annual visits, with 80% of the replicate scans performed by the same sonographer and 20% by a different sonographer; 50% of the replicate scans are read by the same reader and the other 50% by different readers. Results. The overall coefficient of reliability (R) was 0.859 for CBM(max), 0.872 for M(max) and 0.794 for T(max). The reliability for CBM(max) was stable during the 1-year baseline period (R = 0.848 to 0.953) and was uniform among the 23 field centres (R = 0.798 to 0.926). Intra- and inter-reader reliability were 0.915 and 0.872 respectively, and intra-sonographer reliability was 0.866. Conclusion. The results demonstrate that by implementing standardized protocols and strict quality control procedures, highly reliable ultrasonic measurements of carotid artery IMT can be achieved in large multi-national trials. (C) Lippincott Williams and Wilkins.
KW - Atherosclerosis
KW - B-mode ultrasound
KW - Carotid artery
KW - Clinical trials
KW - Reproducibility
UR - http://www.scopus.com/inward/record.url?scp=0034002162&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0034002162&partnerID=8YFLogxK
M3 - Article
C2 - 10694188
AN - SCOPUS:0034002162
SN - 0263-6352
VL - 18
SP - 197
EP - 201
JO - Journal of Hypertension
JF - Journal of Hypertension
IS - 2
ER -