TY - JOUR
T1 - A Simple and Rapid Method for Quantitative HPLC MS/MS Determination of Selected Perfluorocarboxylic Acids and Perfluorosulfonates in Human Serum
AU - Marra, Valentina
AU - Abballe, Annalisa
AU - Dellatte, Elena
AU - Iacovella, Nicola
AU - Ingelido, Anna Maria
AU - De Felip, Elena
N1 - Publisher Copyright:
© 2020 Valentina Marra et al.
PY - 2020
Y1 - 2020
N2 - Per- and polyfluorinated alkyl substances (PFASs) are ubiquitous environmental contaminants, present in the environment and in the human body. They have raised global concern because of their diffusion in the environment, particularly in water, causing cases of human overexposure due to consumption of contaminated drinking water. Human biomonitoring is the most effective way to characterize human exposure to PFASs, and it is important that as many labs as possible could easily perform this kind of analysis. Analytical methods for quantitation of PFAS mixtures in human serum have been developed, but most of them required materials that are not always easily available in all the laboratories. This paper describes a very simple and accessible HPLC MS/MS method of analysis and quantification of 13 perfluorocarboxylic acids and perfluorosulfonate compounds (belonging to the class of per- and polyfluorinated alkyl substances (PFASs)) in human serum. Method development data provide detailed descriptions of the optimization process in terms of sample preparation, laboratory analysis of human serum samples, determination of analytes by HPLC MS/MS, and describing the pump gradient time, working conditions, and acquisition.
AB - Per- and polyfluorinated alkyl substances (PFASs) are ubiquitous environmental contaminants, present in the environment and in the human body. They have raised global concern because of their diffusion in the environment, particularly in water, causing cases of human overexposure due to consumption of contaminated drinking water. Human biomonitoring is the most effective way to characterize human exposure to PFASs, and it is important that as many labs as possible could easily perform this kind of analysis. Analytical methods for quantitation of PFAS mixtures in human serum have been developed, but most of them required materials that are not always easily available in all the laboratories. This paper describes a very simple and accessible HPLC MS/MS method of analysis and quantification of 13 perfluorocarboxylic acids and perfluorosulfonate compounds (belonging to the class of per- and polyfluorinated alkyl substances (PFASs)) in human serum. Method development data provide detailed descriptions of the optimization process in terms of sample preparation, laboratory analysis of human serum samples, determination of analytes by HPLC MS/MS, and describing the pump gradient time, working conditions, and acquisition.
UR - http://www.scopus.com/inward/record.url?scp=85094830304&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85094830304&partnerID=8YFLogxK
U2 - 10.1155/2020/8878618
DO - 10.1155/2020/8878618
M3 - Article
AN - SCOPUS:85094830304
SN - 1687-8760
VL - 2020
JO - International Journal of Analytical Chemistry
JF - International Journal of Analytical Chemistry
M1 - 8878618
ER -